1.Brief introduction
The DC resistance of a transformer is a test item for semi-finished products and finished products in transformer manufacturing, as well as a necessary test item for transformer installation, overhaul, change tapping, handover test, and preventive test. This instrument can check the following conditions: the welding quality of winding joints, whether there is interturn short circuit in the winding, whether each position of the voltage tap changer is in good contact, whether the actual position of the tap changer is consistent with the indicated position, whether the outgoing wire is broken, and whether there is broken strand when multiple strands of wires are wound together.
The instrument adopts a new power supply technology, featuring small volume, light weight, large output current, good repeatability, strong anti-interference ability, and perfect protection function. The instrument is controlled by a high-speed single-chip microcomputer, with a high degree of automation, automatic discharge, and discharge alarm functions. The instrument has high test precision and simple operation, and can realize fast measurement of transformer DC resistance.
2 . Functional features
- English menu, simple and user-friendly interface.
- High automation and easy operation.
- New power technology is adopted, with many current gears and a wide measurement range.
- Suitable for measuring the DC resistance of large and medium-sized transformers with a voltage of 35KV and above
- The protection function is perfect, which can reliably protect against the impact of back electromotive force, and the performance is more reliable.
- With discharge audible alarm and screen tip, the discharge indication is clear to reduce misoperation.
- Intelligent power management technology can effectively reduce the internal heating of the instrument and save energy.
- Micro thermal printer, high-speed, silent, can print test results at any time.
- Vertical chassis structure, convenient for on-site use
3. Technical parameter
| Range | 50A | 40μΩ~400mΩ |
| 20A | 100μΩ~1Ω | |
| 10A | 500μΩ~2Ω | |
| 5A | 1mΩ~4Ω | |
| 2.5A | 2mΩ~8Ω | |
| Accuracy | ±(0.2%±2 numeric) | |
| Resolving power | 0.1μΩ | |
| Working temperature | -10℃~40℃ | |
| Relative humidity | ≤80%RH No condensation | |
| Working power | AC220V±10% 50Hz | |